Showing 16–30 of 32 results
Dimension 1.10 m x 100 mm x 50 mm-Carry foster with Brass strips Wheatstone Bridge, Brass Parts, 1 Meter Long The substantial four-gap bridge has broad, plated brass strips mounted on a wood base. Large plated brass terminals with 4 mm sockets are provided to reduce unwanted resistance to a minimum and the endgaps are closed by removable plated brass strips which are held in position by the terminals. The 0.56 mm constantan wire is stretched along the top of a meter scale subdivided into millimeters and figured every centimeter. the ends of the wire are securely clamped to the terminating strips to reduce end errors to a negligible level
Meter – MO65
Phole’s Commutator
Plug Key
Plug Key Commutator
Pulse Generator 0.1Hz-1Mhz
Bench Type
16000 RPM – Ultra Speed
Self balancing Motor
Kirloskar Compressor
Noise Free & Vibration Free
CRC Sheet duly Powder Coated Stainless
Steel Centrifugal Bowl
LCD Display
Digital Timer
Lock & Dynamic Brake
Imbalance Detector
Acceleration & Deceleration Modes
Microprocessor Based
Speed Regulator
Digital Temperature Controller & Indicator
Complete with Chord & Plug
Max. Speed : 20000 RPM
Max. RCF : 27800xg
Timer : 0-99 min
Motor : Brushless Motor
Temp. Range : Room temperature- to Minus 8°C
Temp. Accuracy : ±2°C
Power : AC 220V 50 Hz 20A
Weight : 60 kg. approx.
Dimension : L-27″ x W-21″ x H-15″ approx.
ISO 9001: 2015
CE Certified
Reversing switch
RF Signal Generator (Transistorized)
SEMICONDUCTOR DIODE CHARACTERISTIC APPARATUS
Service Oscillator AF/RF Oscillator 3MHz-8MHz
Spot Frequency Oscillator
Step Down Transformer
Table Top Front loading Autoclave is also known as Table Top Front loading Sterilizer
It consists of Fast cycle time with Digital timer for Wet & Dry Cycle
After Cycle completion , Water Auto drains to reservoir tank
Table Top Autoclave is completely automatic & has facility of error message
The Chamber is Seamless
Autoclave has Analogue Pressure Display
There is a feasibility to take out instruments from chamber even after electricity fails Mode Selections are as below:
Instrument programs to sterilize metallic devices sterilization temperature : 134°C, sterilization time : 4 minutes & dry time :
15 minutes.
Rubber programs to sterilize rubber & plastic sterilization temperature : 121°C, sterilization time : 20 minutes & dry time : 15 minutes.
Liquid programs to sterilize liquid sterilization temperature : 121°C, sterilization time : 20 minutes & dry time : 15 minutes. Manual Program can be set as per user requirements. Program can be set for pre vacuum, post vacuum sterilization temperature : 121°C~134°C, sterilization time : 1~60 minutes, dry time : 1~60 minutes.
Reservoir Capacity is 3 Litre
There are 3 No Loading Tray Size 150mmx380mmx14mm
Power is 220V 50/60Hz, 15A
Power Consumption is 1800 W
Temperature Range is 121°C (1.1bar)-134°C (2.1bar)
Dry System Heat Drying
Control System is Automatic Micro Processor Based
Display of Table Top Front Loading Autoclave is LED
Size in inch Size in mm Capacity (Ltr)
9 x 18 Inch 225 x 430 mm 17 Ltr
Tapping Key